* FH-1 SERIES SYSTEM | | | Load application | Load cell, force feedback, closed loop system | | Hardness scales FH-1-1 | Rockwell / Superficial Rockwell, HVT, HBT, Hb. | | Hardness scales FH-1-2 | Rockwell / Superficial Rockwell, Brinell, HVT, HBT, Hb. | | Hardness scales FH-1-3 | Rockwell / Superficial Rockwell, Brinell, Vickers, HVT, HBT, Hb. | | Load range FH-1-1 | 1 kgf to 187.5 kgf (2.2 lbf to 413 lbf) | | Load range FH-1-2 | 1 kgf to 250 kgf (2.2 lbf to 551 lbf) | | Load range FH-1-3 | 1 kgf to 250 kgf (2.2 lbf to 551 lbf) | | Test loads | 1, 2, 2.5, 3, 5, 10, 15, 15.6325, 20, 30, 31.25, 45, 50, 60, 62.5, 100, 125, 150, 187.5, 250kgf(2.2, 4.4, 5.5, 5.51, 6.6, 11, 22, 33, 34, 44, 66, 69, 79, 110, 132, 138, 220, 276, 331, 413, 551 lbf) depending on model | | Vickers test range | HV1, HV2, 3, 5, 10, 20, 30, 50, 100, 120kgf (4.4, 6.6, 22, 44, 66, 110, 220 lbf) HVT 50, 100 kgf (110, 220 lbf) | | Brinell test range | HB1/2.5, 5, 10, 31.25 kgf (5.5, 11, 22, 69 lbf) HB2.5/6.25, 15.625, 31.25, 62.5, 187.5 kgf (14, 34, 69, 138, 413 lbf) HB5/25, 62.5, 125 kgf (55, 138, 276 lbf) HB10/100 kgf (220 lbf) HBT2.5/62.5, 187.5 kgf (138, 413 lbf) | | Rockwell scales | A, B, C, D, E, F, G, H, K, L, M, P, R, S, V | | Rockwell superficaial scales | 15N, 30N, 45N, 15T, 30T, 45T, 15W, 30W, 45W, 15X, 30X, 45X, 15Y, 30Y, 45Y | | Scale resolution (depth) | 0.1 micron | | Display | Full color OLED display, testing results, statistics, built-in hardness calculator, program overview, settings, calibration, and many more | | Standards | Complies with, or exceeds, EN/ISO, ASTM, and JIS standards | | Test cycles | Fully automatic, Load, Dwell, Uoload | | Force control | 1-99seconds | | Data output | USB-2 (RS-232) | | Specimen accommodation | Height 300mm (11.81") Throat 200mm (7.87") | | Operating Temperature Range | 5℃ to 40℃ (41℉ to 104℉) | | Operating Humidity Range | 10% to 90% non-condensing | | Weight | 110kg (243lbs) | |
|
FH-2 SERIES SYSTEM | | | Load application | Load cell, force feedback, closed loop system | | Hardness scales FH-2-0 | Rockwell / Superficial Rockwell, HVT, HBT, and H Ball indentation | | Hardness scales FH-2-1 | Rockwell / Superficial Rockwell, Brinell, Vickers, HVT, HBT, and H Ball indentation | | Load range FH-2-0 | 1 kgf to 187.5 kgf (2.2 lbf to 413 lbf) | | Load range FH-2-1 | 1 kgf to 250 kgf (2.2 lbf to 551 lbf) | | Test loads | 1, 2, 2.5, 3, 5, 10, 15, 15.6325, 20, 30, 31.25, 45, 50, 60, 62.5, 100, 125, 150, 187.5, 250kgf(2.2, 4.4, 5.5, 5.51, 6.6, 11, 22, 33, 34, 44, 66, 69, 79, 110, 132, 138, 220, 276, 331, 413, 551 lbf) depending on model | | Vickers test range | HV1, HV2, 3, 5, 10, 20, 30, 50, 100, 120kgf (4.4, 6.6, 22, 44, 66, 110, 220 lbf) HVT 50, 100 kgf (110, 220 lbf) | | Brinell test range | HB1/2.5, 5, 10, 31.25 kgf (5.5, 11, 22, 69 lbf) HB2.5/6.25, 15.625, 31.25, 62.5, 187.5 kgf (14, 34, 69, 138, 413 lbf) HB5/25, 62.5, 125 kgf (55, 138, 276 lbf) HB10/100 kgf (220 lbf) HBT2.5/62.5, 187.5 kgf (138, 413 lbf) HBT5/250 kgf (551 lbf) | | Rockwell scales | A, B, C, D, E, F, G, H, K, L, M, P, R, S, V | | Rockwell superficaial scales | 15N, 30N, 45N, 15T, 30T, 45T, 15W, 30W, 45W, 15X, 30X, 45X, 15Y, 30Y, 45Y | | Plastic Ball indentation | Complies with ISO 2039/1 | | Scale resolution (depth) | 0.1 micron | | Display | Large high definition industrial touch screen can also be operated by mouse and keyboard | | Standards | Complies with, or exceeds, EN/ISO, ASTM, and JIS standards | | Test cycles | Fully automatic, Load, Dwell, Uoload | | Force control | 1-99seconds | | Data output | USB-2 (6) RJ-45 LAN, W-LAN, (RS-232) | | Specimen accommodation | Height 300mm (11.81") Throat 200mm (7.87") | | Weight | 110kg (243lbs) | | Operating Temperature Range | 5℃ to 40℃ (41℉ to 104℉) | | Operating Humidity Range | 10% to 90% non-condensing |
|